PT-1000SIT Cable sensor Cable resistance thermometer

Cable resistance thermometer with safe disconnection
Length 600 mm


Connection type: 2-wire circuit
Resistance value: 1000 Ω at 0°C, in accordance with DIN EN 60751:2009
Tolerance class B, ± 0.30°C, in accordance with DIN EN 60751:2009
Max. Operating current: 0.3 mA
Measuring range: -55°C...+190°C
Supply cable: permanently connected single wire, Cu-nickel-plated / PTFE
Colour: red/white


€70.21
Incl. 19% Tax, plus Shipping
Delivery within 85 to 87 days within Germany, reordering within 84 days.
Not in stock, will be ordered for you.
SKU
19-00009
PT-1000SIT Cable sensor Cable resistance thermometer is available to buy in increments of 1

The sensors are mainly used for thermal monitoring of the winding of electrical machines. They are also suitable for measuring the temperature in laboratory and test facilities, in gaseous, liquid or solid media.

Caution:

During installation, care must be taken to ensure that the cable and insulation are not damaged. The supply line must be laid with strain relief. Avoid mechanical loads on the sensor. Cable length corresponds to sensor tip to cable end. The sensor is suitable for inverter-fed machines up to 1000 V. System voltage approved in accordance with DIN EN 61800-5-1 and DIN EN 50178 ("Safe isolation").
Height correction for surge voltage testing at an altitude of 2000 m above sea level in accordance with overvoltage category III

<img alt="" height="722" src="https://www.shop-traub.com/media/wysiwyg/Images/PT-1000SIT-tech-daten.JPG" width="633" />

More Information
Item name PT-1000SIT Cable sensor Cable resistance thermometer
SKU 19-00009
Weight 0.007600
Manufacturer number PT-1000SIT
Manufacturer EPHY MESS
Country of manufacture Germany
Traub order number PT-1000SIT
Commodity code 90259000

EPHY MESS GmbH
Berta-Cramer-Ring 1
65205 Wiesbaden
Deutschland
hanna.bicer@ephy-mess.de