ESS31-TC-002-DC24V-8A ETA Electronic circuit breaker

Electronic circuit breaker with current limiter
Manual on/off switch (pressure/pressure actuation)
Operating voltage DC 24 V
Rated current 8A

€85.64
  • Buy 10 for €81.62 each and save 5%
  • Buy 25 for €74.93 each and save 13%
  • Buy 50 for €68.91 each and save 20%
  • Buy 100 for €66.90 each and save 22%
Incl. 19% Tax, plus Shipping
Delivery within 29 to 31 days within Germany, reordering within 28 days.
ESS31-TC-002-DC24V-8A ETA Electronic circuit breaker has a minimum order quantity of 4 pieces
Not in stock, will be ordered for you.
SKU
24-01834
ESS31-TC-002-DC24V-8A ETA Electronic circuit breaker is available to buy in increments of 1
Zubehör

Artikel dem Warenkorb hinzufügen oder Alles auswählen

The ESS31-T. electronic circuit breaker for DC 24 V applications is just 12.5 mm wide and selectively protects all DC 24 V load circuits, thereby increasing the availability of machines and systems. This is achieved by a combination of active electronic current limitation in the event of a short circuit and an overload cut-out at typ. 1.2 x IN. The device reacts faster than frequently used DC 24 V switching power supplies without tripping quickly, thus preventing fatal voltage dips in the supply. The ESS31-T can be snapped directly onto the top-hat rail and therefore offers quick and flexible installation for device groups with several circuits.
ESS31-T works with a single switch-off characteristic for all load types. Capacitive loads up to 40,000 μF can also be operated very easily. Fixed currents from 0.5 A to 12 A are available. The integrated fail-safe element (fuse) is adapted to the rated device current and can therefore be easily matched to the wired cable cross-section. This makes planning much easier.

Due to the approval according to UL1077 "Supplementary Protector" and the UL Listed approval according to UL60947/UL508, these circuit breakers can also be used in applications according to UL 508A "Industrial Control Panels" without any problems and are also suitable for "field wiring". Furthermore, the integrated galvanic isolation offers an additional level of safety, as a circuit breaker is actually "switched OFF" in the "OFF" state.


Key features:

  • Can be mounted on the mounting rail
  • Wiring via feed rail LINE+ and 0 V
  • Galvanic isolation in the event of a fault
  • Active linear current limitation
  • Capacitive loads up to 40,000 μF
  • Fixed rated currents 0.5 A...12 A
  • Approvals: UL, NEC Class 2, VDE

Your benefit:

  • Safe to use worldwide, as approved in accordance with EN/IEC60934 (VDE) and UL1077 (Supplementary Protector), UL 1310 (NEC Class 2)
  • Simplifies maintenance and troubleshooting, as load circuits are actually switched off thanks to galvanic isolation
  • Simplifies planning thanks to active current limitation as a clear planning parameter
  • Saves costs and time thanks to quick and flexible installation including integrated power distribution solution


Technical data (TU = 25 °C, UB = DC 24 V):

operating data
operating voltage UB dC 24 V (18...30 V)
rated current IN fixed currents: Type ESS31-TC-...: 0.5 A; 1 A; 2 A; 2 A CL2; 3 A; 3 A CL2;
3.6 A; 3.6 A CL2; 4 A; 6 A; 8 A; 10 A; 12 A

adjustable: 1 A/2 A or 3 A/6 A
quiescent current I0 in ON state: typ. 8 mA depending on signal output
tripping current (bimetal) typ. 0.4 A
(only in the event of a fault, until galvanic switch-off)

signalling of the operating status via

  • Multi-coloured LED:
    Green:
    - device switched on (S1 = ON)
    Load circuit energised
    Orange:
    - overload or short circuit up to
    electronic switch-off
    Red:
    - Device switched off electronically
    Load circuit switched off
    - Undervoltage (UB < 8 V)
    OFF:
    - Manually switched off (S1 = OFF)
    Load circuit is electrically isolated
    or device is de-energised

  • Potential-free signal contact

  • On/off position of switch S1

load circuit
load output power - MOSFET switching output (positive switching)

Overload cut-off (ÜL) and
Short-circuit current cut-off

typ. 1.2 x IN with active current limitation

switch-off times for electron. Switch-off

for galvanic isolation

see time / current characteristic. overload switch-off time typ. 500 ms

short-circuit switch-off time depending on rated current (see Table 1)

typ. 5 s

temperature switch-off

Internal temperature monitoring with galvanic isolation

undervoltage monitoring
of the load output

with hysteresis, no reset necessary:
OFF at UB < 14 V
ON at UB > 17 V

switch-on delay tStart typ. 2 ms
after each switch-on and after the application of UB
capacitive loads up to 40,000μF
freewheeling circuit external freewheeling diode recommended for inductive loads
parallel connection of several load outputs not permitted
signalling output eSS31-TC-001/-002
electrical data

potential-free signal contact
max. DC 30 V / 2 A, min. DC 12 V / 10 mA

normal state LED green

UB is present and switch S1 is ON and
no overload, no short circuit

oFF status LED off

Device switched off (switch S1 to OFF)
Load circuit is electrically isolated
Operating voltage UB missing

error message, signal output
fault status LED orange overload condition > 1.2 x IN until electronic switch-off

fault status LED red

eSS31-TC-001

eSS31-TC-002

electronic switch-off after overload, short circuit or undervoltage

single signal, NO contact open, terminals 13-14

single signal, normally closed contact closed, terminals 11-12

general data
fail-safe element

back-up fuse for ESS31-T.. not necessary, as a redundant fail-safe element

is integrated (fuse element)

connection terminals lINE+ / LOAD+ / 0V


Screw connections
Connection capacity (conductor cross-section) flexible with wire end ferrule

m4

o./m. Plastic sleeve
Multi-conductor connection (two conductors of the same cross-section)

0.5 - 10 mm2

rigid / flexible
flexible with ferrule

0.5 - 4 mm2

without plastic sleeve
flexible with TWIN ferrule

0.5 - 2.5 mm2

with plastic sleeve

stripping length

tightening torque (EN 60934)

0.5 - 6 mm2

10 mm

1.5 - 1.8 Nm

connection terminals signal connections

Screw connections
Connection capacity (conductor cross-section) flexible with wire end ferrule
m3

o./m. Plastic sleeve
Stripping length
Tightening torque (EN 60934)

0.25 - 2.5 mm2
8 mm
0.5-0.6 Nm
housing material plastic
enclosure mounting mounting rail to EN 60715-35x7.5
ambient temperature 0...+50 °C (without condensation, see EN 60204-1)
storage temperature -40...+70 °C
humidity Heat 96 hours/95 % relat. Humidity/40 °C according to IEC 60068-2-78, Test Cab.
Climate class 3K3 according to EN 60721
vibration resistance 3 g, test according to IEC 60068-2-6, test Fc
protection class
Enclosure IP20 EN 60529
Terminals IP20 EN 60529

eMC requirements
(EMC Directive, CE marking)
interference emission: EN 61000-6-3
Interference immunity: EN 61000-6-2
insulation coordination
(IEC 60934)
0.5 kV/pollution degree 2
Reinforced insulation in the actuation area
insulation resistance
(off state)

> 100 MΩ (DC 500 V) between
LINE (+) and LOAD (+)

dielectric strength
- Actuation range
- Installation range
- Load circuit signal contact

(see also dimensional drawing)
Test voltage AC 1 000 V
Test voltage AC 500 V


conformity / approvals

cE mark

insulation resistance
(off state)
> 100 MΩ (DC 500 V) between
LINE (+) - LOAD (+)
installation dimensions (W x H x D)
12.5 x 80 x 83 mm
(tolerances in accordance with DIN ISO 286 Part 1 IT13)

actuating forces
Switch-on
Switch-off

5...8 N
7...10 N

weight approx. 70 g


Approvals:

test centre Test standard rated voltage rated current range

File-
Certificate
No.

uL uL 2367 dC 32 V 0.5 A...12 A e306740
uL

uL 1310
NEC Class 2

dC 28 V

0.5 , 1 A, 2 A, 3 A, 3.6 A

e306740
uL

uL 1077
C22.2 No.
235-04

dC 24 V

0.5 A...12 A

e67320
uL

cULuslisted UL 60947-4-1

dC 24 V

0.5 A...12 A

e362760
vDE

iEC/EN
60934
(VDE 0642)

dC 24 V 0.5 A...12 A 40039681

Table 1: Voltage drop, current limitation, max. load current

Rated current
I
N

typ. Voltage drop
UON at IN

active current
limitation (typ.)

Switch-off
Time
IKS
typ. 1)

Switch-off

Time
IÜL
typ. 2)

Fail-safe
Element

max. load current
at 100 % ED

tU = 40 °C

tU = 50 °C

0,5 A

90 m V

1.2 x IN

500 ms

500 ms

2 A

0,5 A

0,5 A

1 A

100 mV

1.2 x IN

500 ms

500 ms

2 A

1 A

1 A

2 A

110 m V

1.2 x IN

500 ms

500 ms

4 A

2 A

2 A

2 A CL2

130 mV

1.2 x IN

500 ms

500 ms

4 A

2 A

2 A

3 A

150 m V

1.2 x IN

500 ms

500 ms

6,3 A

3 A

3 A

3 A CL2

200 mV

1.2 x IN

500 ms

500 ms

4 A

3 A

3 A

3,6 A

155 mV

1.2 x IN

350 ms

500 ms

6,3 A

3,6 A

3,6 A

3.6 A CL2


250 mV

1.05 x IN

450 ms

500 ms

4 A

3,6 A

3,6 A

4 A

160 m V

1.2 x IN

280 ms

500 ms

6,3 A

4 A

4 A

6 A

170 m V

1.2 x IN

150 ms

500 ms

10 A

6 A

5 A

8 A

190 mV

1.2 x IN

280 ms

500 ms

15 A

8 A

7 A

10 A

210 mV

1.2 x IN

200 ms

500 ms

15 A

10 A

9 A

12 A

220 mV

1.2 x IN

110 ms

500 ms

20 A

12 A

10,8 A

More Information
Item name ESS31-TC-002-DC24V-8A ETA Electronic circuit breaker
SKU 24-01834
Weight 0.067800
Country of manufacture Germany
Connection type Main connections P10 flat plug DIN 46244-A6.3-0.8
Signal output 2 Signal contact NC contact
Design: Communication, interface 0 ohne Steuereingang
Series ESS31-T
Version 0 mit galvanischer Trennung im Fehlerfall
Manufacturer E-T-A
Manufacturer number ESS31-TC-002-DC24V-8A
Additional function 0 ohne
Actuating element W Standard rocker switch
Undervoltage module none
Operating voltage DC 24 V Nennspannung DC 24 V
Number of poles 1-pole thermally protected
Mounting type TC Mounting rail fastening
Characteristic Medium time-lag tripping characteristic (standard)
Commodity code 85362010
Traub order number ESS31-TC-002-DC24V-8A