ESS22-TA-001-DC24V-4A ETA Electronic circuit breaker
Electronic circuit breaker
DIN rail mounting with ON/OFF slide actuation
Operating voltage DC 24 V
Rated voltage 4A
- Buy 10 for €147.55 each and save 5%
- Buy 25 for €135.46 each and save 12%
- Buy 50 for €124.57 each and save 20%
- Buy 100 for €120.94 each and save 22%
The ESS22-T device extends the "Electronic circuit breakers" product group for DC 24 V applications. This is a two-pole version with galvanic isolation. The ESS22-T therefore fulfils the requirements of the Machinery Directive 2006/42/EC and the associated standard EN 60204-1 "Safety of machinery, electrical equipment of machines", section 9.4.3.1
The combination of active electronic current limitation in the event of a short circuit and an overload cut-out from 1.1 x IN provides selective, two-pole protection for DC 24 V load circuits. The ESS22-T can be snapped directly onto the top-hat rail and therefore offers quick and flexible installation for device groups with several DC 24 V circuits that are supplied by switched-mode power supplies or transformer power supplies.
DC 24 V switched-mode power supplies are used very frequently in automation technology. However, in the event of an overload, they regulate the output voltage that is to supply all connected loads. If a fault occurs in a single load in the system, the voltage in all other load circuits also drops. This often results not only in an undefined fault state, but also in the machine or system coming to a standstill.
This is precisely where the ESS22-T intervenes by reacting faster than the switching power supply to the overload condition. The maximum possible overcurrent is always limited to typically 1.4 times the selected rated current. This makes it possible to switch on capacitive loads up to 20,000 μF, but it only switches off in the event of an overload or short circuit. The rated current is available in fixed values of 0.5 A...10 A to adapt to the load conditions. Operating and fault states are indicated by a visual display and via signal contacts. Remote operation is optionally possible via an electrically isolated control input.
The manual ON/OFF switch directly on the device allows targeted commissioning of individual load circuits. As soon as the ESS22-T detects an overload or short circuit in its load circuit, it blocks the load output transistor and thus interrupts the current flow in the faulty circuit; in addition, the load output is galvanically isolated on two poles by a mechanical switching element. Once the fault has been rectified, the load output of the ESS22-T is reactivated manually by pressing the ON/OFF switch directly on the device or optionally via the galvanically isolated reset input or via the control input.
Key features:
- Two-pole electronic circuit breaker with galvanic isolation at the load output
- "LOAD+ path" 2-fold protected with electronic fuse and failsafe element
- "LOAD- path" 2-fold protected with electronic fuse and failsafe element
- Selective load protection, electronic switch-off characteristic
- Active current limitation when switching on capacitive loads up to 20,000 μF, DC motors and in the event of overload/short circuit
- Rated current selectable in fixed current levels 0.5 A...10 A
- Operating voltage monitoring for undervoltage
- Manual on/off switch (ON/OFF) on the device
- Option: Galvanically isolated control input for ON/OFF
- Option: Galvanically isolated reset input RE
- Visual signalling via multicoloured LED
- 2 signal contacts (NC contact and NO contact) Width 22.5 mm
- For direct top-hat rail mounting
Technical data:
| operating data | |
| operating voltage UB | dC 24 V (18...32 V) |
| rated current IN | fixed currents: 0.5 A, 1 A, 2 A, 3 A, 4 A, 6 A, 8 A, 10 A |
| quiescent current I0 | in ON state: typ. 27 mA with signal output: typ. 37 mA |
|
signalling of the operating status via |
|
| load circuit | |
| load output | power - MOSFET and relay switching output with galvanic isolation, plus and minus switching |
| overload switch-off (ÜL) | typ. 1.1 x IN (1.05...1.35 x IN) |
| short-circuit current IK | active current limitation typ. 1.4 x IN (see Table 1) |
| switch-off times | see time/current characteristic typ. 3 s for Iload > 1.1 x IN typ. 100 ms...3 s for Iload > 1.4 x IN |
| temperature switch-off |
internal temperature monitoring with |
| operating voltage monitoring for undervoltage |
oFF at typ. UB < 16.0 V ON at typ. UB > 17.5 V with automatic OFF and ON switching |
| switch-on delay tStart | typ. 0.5 s after each switch-on, after reset and after the application of UB |
| switching off the load circuit | is double-pole with galvanic isolation - Manually on the device with the ON/OFF switch (OFF) - After an overload/short circuit Switch-off - Via external control input - In the event of undervoltage - In the absence of operating voltage |
| resetting (RESET) or switching on again after an overload or short-circuit switch-off |
- First rectify the external overload or short-circuit fault - Manual RESET on the device via switch: OFF/ON - No reset during operating voltage interruptions (the status is saved) - No reset possible via the external control input IN - External reset optionally possible via reset input RE |
| freewheeling circuit | external freewheeling diode recommended for inductive load |
| parallel connection of several load outputs | not permitted |
| signal output ESS22-TA-0x1 | |
| electrical data | potential-free signal contact 1 NC contact, terminal 11-12 (closed in off or fault state) 1 NO contact, terminal 13-14 (open in off or fault state) max. DC 30 V/0.5 A, min. 10 V/10 mA |
| error pattern | signal output is in error state: - Manually on the device with the ON/OFF switch (OFF) - After an overload/short circuit Switch-off - External control input (OFF) - Undervoltage - If there is no operating voltage |
| control input IN+ / IN- ESS22-TA-01x / ESS22-TA-03x | |
| electrical data | control input (IN+/IN-) is electrically isolated from the load circuit (optocoupler) Voltage max. + DC 32 V High > DC 12 V ≤ DC 32 V (switch-on) Low ≤ DC 5 V > 0 V (switch-off) Current consumption typ. 3...9 mA (DC +12 V...32 V) |
| reset function | eSS22-TA-03x A disabled load output (disabled after an overload/short-circuit (switch-off) can be switched back on by the external control input . To do this, the control input must be switched off for at least >100 ms. |
| links | manual ON/OFF switch on the device is linked to the external control input IN+ with an AND function. |
| reset input RE+ / RE- ESS22-TA-02x | |
| Electrical data | reset input (RE+/RE-) is galvanically isolated from the load circuit (optocoupler) Voltage max. + DC 32 V High > DC 12 V ≤ DC 32 V Low ≤ DC 5 V > 0 V Current consumption typ. 3...9 mA (DC +12 V...32 V) RESET - pulse/edge from low (min. 100 ms) to high (min. 100 ms) |
| reset signal RE | a disabled load output (disabled after an overload/short-circuit switch-off) can be switched on again by an external reset pulse (+ DC 24 V). a common reset signal can also be applied simultaneously to several ESS22-T devices , switched-on devices remain unaffected. |
| general data | |
| fail-safe element | integrated fail-safe element adapted to the rated current (fuse element) |
| connection terminals | |
| screw connections Connection capacity (conductor cross-section) rigid/flexible Stripping length Tightening torque (EN 60934) Loop-through option |
m3 0.14 - 2.5 mm2 (AWG 26-14) 8 mm 0.5 - 0.6 Nm LINE+ and LINE connections are double. maximum continuous load for power supply 10 A |
| housing material | plastic |
| enclosure mounting | top-hat rail to EN 50022-35x7.5 |
| ambient temperature | 0...50 °C (without condensation, see EN 60204-1) |
| storage temperature | -20...70 °C |
| humidity Heat | 96 hours/95 % relat. Humidity/40 °C according to IEC 60068-2-78, Test Cab. Climate class 3K3 according to EN 60721 |
| vibration resistance | 3 g, test according to IEC 60068-2-6, test Fc |
| protection class | enclosure IP20 DIN 40050 Terminals IP20 DIN 40050 |
| standards, regulations | cE mark in accordance with EMC directive Interference emission: EN 61000-6-3 Interference immunity: EN 61000-6-2 Surge voltages: EN 61000-4-5 (± 1 kV symmetrical) |
| insulation coordination 0.5 kV/pollution degree 2 (IEC 60934) |
0.5 kV/pollution degree 2 |
| insulation voltage | dC 500 V Between the galvanically isolated areas: load circuit in off-state, signal input and signal outputs |
| dielectric strength | max. DC 32 V |
| reverse polarity protection | reverse polarity protection |
| installation dimensions (W x H x D) | see dimensional drawing (tolerances according to DIN ISO 268 Part 1 ± IT 13) |
| weight | approx. 110 g |
Approvals:
| test centre | rated voltage | rated current range |
| vDE (EN 60934) | dC 24 V | 0,5...10 A |
| uL 1077 in preparation | dC 24 V | 0,5...10 A |
| Item name | ESS22-TA-001-DC24V-4A ETA Electronic circuit breaker |
|---|---|
| SKU | 24-01857 |
| Weight | 0.102600 |
| Signal input | 0 without signal input |
| Country of manufacture | Germany |
| Connection type Main connections | P10 flat plug DIN 46244-A6.3-0.8 |
| Signal output | 1 with signal contacts: 1 NC contact, 1 NO contact |
| Series | ESS22-T |
| Version | 0 mit zweipoliger galvanischer Trennung am Lastausgang |
| Manufacturer | E-T-A |
| Manufacturer number | ESS22-TA-001-DC24V-4A |
| Actuating element | W Standard rocker switch |
| Undervoltage module | none |
| Operating voltage | DC 24 V |
| Number of poles | 1-pole thermally protected |
| Mounting type | TA mounting rail attachment, without signal contact |
| Characteristic | Medium time-lag tripping characteristic (standard) |
| Commodity code | 85362010 |
| Traub order number | ESS22-TA-001-DC24V-4A |