EBU10-TA1-003-AC230V-B-16A ETA Electronic circuit breaker

Electronic overcurrent protection circuit breaker
AC 230 V
Rated current 16 A
€216.07
  • Buy 10 for €205.94 each and save 5%
  • Buy 25 for €189.07 each and save 12%
  • Buy 50 for €173.87 each and save 20%
  • Buy 100 for €168.80 each and save 22%
Incl. 19% Tax, plus Shipping
Delivery within 29 to 31 days within Germany, reordering within 28 days.
EBU10-TA1-003-AC230V-B-16A ETA Electronic circuit breaker has a minimum order quantity of 1 pieces
Not in stock, will be ordered for you.
SKU
24-01525
EBU10-TA1-003-AC230V-B-16A ETA Electronic circuit breaker is available to buy in increments of 1

The electronic circuit breaker type EBU10-T, Electronic Breaker Unit, provides selective overcurrent protection for AC 230 V UPS systems. The unit consists of a miniature circuit breaker that is approved for short-circuit disconnections of up to 10 kA and an adjustable electronic unit that takes over measuring and evaluation tasks in a targeted manner. The product is available in the LS rated currents 4 A, 6 A, 10 A and 16 A characteristic B and C and is operated directly at the outgoing feeder of the respective UPS.

UPS systems often do not provide sufficient power in the event of a short circuit to trigger conventional miniature circuit breakers. The electronic AC circuit breaker can be individually adapted to the UPS and thus reliably trips in the event of a short circuit. Due to the optimum setting of the rated load current, an overload in the load circuit is also specifically detected and switched off.

Fatal disconnection of the entire output voltage of the UPS system is thus excluded.uPS systems can be dimensioned about 1/3 smaller than before thanks to the Electronic Breaker Unit, EBU10-T
, because no additional line reserves have to be kept available for tripping. EBU10-T increases system availability, reduces overall costs and noticeably simplifies planning.


Key features:

Electronic overcurrent protection using electronic AC circuit breakers is ideal for selective protection of uninterruptible power supplies (UPS) in industrial plants. With EBU10-T, energy security is ensured by AC UPS systems.

  • Increase in system availability through effective fuse protection
  • Reduction of total costs through 1/3 more efficient design
  • Simplification of planning due to variable overcurrent protection

Technical data:

operating data
rated voltageUN aC 230 V ±10%

rated current seriesIN


4 A, 6 A, 10 A, 16 A
frequency 50 Hz
rated insulation voltage aC 250 V
rated voltage
and rated current range
Signal contact

dC 110 V / 0.3 A - 33 W
DC 30 V / 1.1 A - 33 W
AC 120 V / 0.5 A - 60 VA
AC 240 V / 0.25 A - 60 VA

minimum load signal contact
(valid for normal
industrial environment, no aggressive gases)

3 mA at DC 24 V

typical electrical operating values
voltage drop in V at load 1 x IN

iN (A))

v

4 6 10 16
0,77 0,53 0,35 0,3

Insulation coordination of signalling
Rated impulse voltage: 2.5 kV
Note: The Si contacts are not suitable for connection
to SELV control voltage.

enclosure mounting mounting rail
storage temperature -40 °C...+70 °C
connections

- Screw terminals
on the input side (cage terminal)
Cross-connection with
pin comb rail possible
- Push-in terminal on the output side
and on signal contacts

connection cross-section

line
N
Load
Si


1...25 mm²
1...10 mm²
0.5...4 mm²
0.5...1.5 mm²
mass

approx. 230 g 1-pole
approx. 330 g 2-pole


Approval:

test centre test standard File No. rated voltage rated current range
uL uL 2367 E306740 dC 24 V 1 A...10 A
uL

uL 1310
NEC Class2

E306740 dC 24 V

1 A, 2 A,
3 A, 4 A

uL

uL60947 / cULus508listed

e492388

dC 24 V

1 A...10 A

More Information
Item name EBU10-TA1-003-AC230V-B-16A ETA Electronic circuit breaker
SKU 24-01525
Weight 0.029000
Signal input 0 without signal input
Country of manufacture Germany
Connection type Main connections P10 flat plug DIN 46244-A6.3-0.8
Signal output 3 Signal contact changer (collective signalling)
Design: Communication, interface Einstellbarkeit IN UPS + IN Load
Series EBU10-T
Version mit galvanischer Trennung
Manufacturer E-T-A
Manufacturer number EBU10-TA1-003-AC230V-B-16A
Additional function Kennlinie B thermisch 1.05 - 1,30 IN / magnetisch 3.2 - 4,8 IN
Actuating element Manual ON/OFF/Reset button
Undervoltage module none
Operating voltage AC 230 V
Number of poles 1-pole
Mounting type T Mounting rail fastening
Characteristic Medium time-lag tripping characteristic (standard)
Commodity code 85362010
Traub order number EBU10-TA1-003-AC230V-B-16A

E-T-A
Elektrotechnische Apparate GmbH
Industriestraße 2-8
90518 Altdorf b. Nürnberg
Deutschland
order@e-t-a.de
e-t-a.de