CPC12EC-T1-001 ETA BUS-CONTROLLER with EtherCat
ControlPlex® SYSTEM CPC12
In mechanical and plant engineering, the demands on product quality and the stability of the manufacturing process are constantly increasing. The Control-Plex® System CPC12 permanently records, analyses and processes measurement data. This creates the necessary transparency to recognise changes in the production process at an early stage and counteract them accordingly.
The CPC12 bus controller expands the REX system to include connection to various fieldbus connections. This makes DC 24 V power distribution and fuse protection more transparent than ever. The REX12D and REX22D electronic circuit breakers record the status and measured values of each load circuit and transmit them to the bus controller. This provides system operators and maintenance personnel with all the information they need to recognise changes and possible malfunctions at an early stage.
CPC12 bus controller
The CPC12 bus controller is connected to the EM12-T power supply module and supplied with power. It also has a separate DC 24 V power supply and thus enables an independent supply to the circuit breakers. The bus controller records all status information and measured values of the circuit breakers. This data is visualised using the internal web server. The data is also made available to the higher-level control systems via the fieldbus interface.
Technical data (TU = 25 °C, UB = DC24 V)
Operating voltage UB DC 24 V (18...30 V)
Reverse polarity protection Yes
Quiescent current I0 typ. 75 mA
Power supply (XD1)
Connection terminal 0.2 mm2 to 1.5 mm2
(Push-In) AWG24 - AWG16
Stripping length 8 mm
PROFINET interface (XF1, XF2)
RJ45 connection to the PROFINET bus system.
The installation and wiring regulations of the PROFIBUS User Organisation e.V. (PNO) must be observed when wiring and connecting to the PROFINET bus system.
ETHERNET interface (X1)
RJ45 Communication interface to the web server.
IP reset button Resetting the IP address
(interface X1) by pressing the button for at least 3 s.
Dimensions 12.5 x 80 x 98 mm
Weight approx. 70 g
| Item name | CPC12EC-T1-001 ETA BUS-CONTROLLER with EtherCat |
|---|---|
| SKU | 24-02015 |
| Weight | 0.102100 |
| Signal input | 0 without signal input |
| Country of manufacture | Germany |
| Connection type Main connections | P10 flat plug DIN 46244-A6.3-0.8 |
| Signal output | 0 without signal output |
| Series | CPC |
| Manufacturer | E-T-A |
| Manufacturer number | 0CPC12002 |
| Additional function | PROFINET-Schnittstelle (XF1, XF2) |
| Actuating element | W Standard rocker switch |
| Undervoltage module | none |
| Operating voltage | DC 24 V |
| Number of poles | 1-pole thermally protected |
| Rated current range | 40A |
| Mounting type | T Mounting rail fastening |
| Characteristic | Medium time-lag tripping characteristic (standard) |
| Commodity code | 8517 62 00 |
| Traub order number | CPC12EC-T1-001 |
E-T-A
Elektrotechnische Apparate GmbH
Industriestraße 2-8
90518 Altdorf b. Nürnberg
Deutschland
order@e-t-a.de