8340-F410-P1K1-A3H142-5A ETA Hydraulic magnetic circuit breaker
E-T-A Hydraulic magnetic circuit breaker
2-pole protected, hydraulic magnetic delayed
Without auxiliary contacts
Rated current range 5 A
- Buy 10 for €85.92 each and save 16%
- Buy 100 for €49.72 each and save 51%
Artikel dem Warenkorb hinzufügen oder Alles auswählen
Single and multi-pole circuit breaker with magnetic or hydraulic-magnetic tripping, toggle lever actuation, front mounting, various characteristic curves and optional auxiliary contacts. A precise switching mechanism ensures unaffected free tripping and reliable disconnection even with the smallest overcurrents. Low temperature sensitivity at nominal load. Complies with the appliance circuit breaker standard EN 60934 (IEC 60934): S-type, HM or MO.
Typical areas of application
Power supplies, switchgear, control and regulation technology, telecommunications, fixed and mobile networks
Technical data
| rated voltage |
3 AC 415 V; AC 240 V (50/60 Hz); DC 80 V |
| nominal current range | 0.02...50 A DC 0.02...30 A AC |
| auxiliary circuit | aC 240 V 6 A DC 28 V 3 A DC 65 V 1 A DC 80 V 0.5 A |
| lifetime | 3 AC 415 V, AC 240 V: 0.02...30 A 6,000 switching cycles with 1 x IN, inductive 10,000 switching cycles with 1 x IN, ind.arm DC 80 V: 0.02...25 A 6,000 switching cycles with 1 x IN, inductive 0.02...30 A 10 000 switching cycles with 1 x IN, ind.arm |
| ambient temperature | -40 °C...85 °C |
|
insulation coordination |
2.5 kV/2 (IEC 60664) Reinforced insulation in the actuating range |
| dielectric strength Actuation range Line to load Pole to pole (2- and 3-pole) Main 3-pole) Main to auxiliary circuit Switching to tripping circuit (version X) |
test voltage AC 3 000 V Test voltage AC 1 500 V Test voltage AC 1 500 V Test voltage AC 3 000 V Test voltage AC 1 500 V |
| insulation resistance | > 100 MΩ (DC 500 V) |
| switching capacity 6 x IN with AC; IEC 60934 - Test series E |
6 x IN for AC; 4 x IN for DC |
| switching capacity (UL 1077) | aC: 1-pole AC 240 V/3 500 A AC 240 V/3 500 A 2-pole AC 240 V/3 500 A AC2 40 V/5 000 A 3-pole 3 AC 240 V/3 500 A 3 AC 240 V/5 000 A dC: |
| protection class (IEC 60529) | actuation range IP40 Connection range IP00 |
| vibration resistance | (UL 1077) 0.02...20 A 25...30 A AC: 1-pole AC 240 V/3 500 A AC 240 V/3 500 A 2-pole AC 240 V/3 500 A AC2 40 V/5 000 A 3-pole 3 AC 240 V/3 500 A 3 AC 240 V/5 000 A DC: 1-pole 0.02...50 A DC 80 V/3 500 A 2-pole 0.02...30 A DC 80 V/3 500 A |
| vibration resistance For characteristic curves F1, F2: |
installation position rocker arm downwards: at 0.9 x IN 10 g (57-2000 Hz) ± 0.76 mm (10-57 Hz) Other installation positions: 10 g (57-2000 Hz) at IN all mounting positions at 0.8 x IN 10 g (57-2000 Hz) ± 0.76 mm (10-57 Hz) Test in accordance with IEC 60068-2-6, test Fc, 10 frequency cycles/axis |
| shock resistance Shock direction 1, 2, 3, 4, 5: Shock direction 6: Characteristic curves F1, F2: |
100 g (11 ms) at IN 100 g (11 ms) at 0.8 x IN 100 g (11 ms) at 0.8 x IN Test in accordance with IEC 60068-2-27, Test Ea |
| corrosion resistance | 96 hours in 5 % salt spray, Test in accordance with IEC 60068-2-11, test Ka |
| moisture test | 240 hours in 95 % relative humidity, Test in accordance with IEC 60068-2-78, Test Cab |
| mass | approx. 65 g per pole |
Approvals
| test centre | test standard | rated voltage | rated current range |
| vDE |
iEC / EN |
aC 240/415 V AC 240 V DC 80 V |
0.02 A...30 A 0.02 A...30 A 0.02 A...50 A |
| uL | uL 1077 | aC 250 V DC 80 V DC 80 V |
0.02 A...30 A 0.02 A...50 A 100 A (2 poles in parallel) |
| uL | uL 489A | dC 80 V | 0.05 A...30 A (1 + 2 poles) |
| cSA | c22.2 No 235 |
aC 250 V DC 80 V |
0.02 A...30 A 0.02 A...30 A |
| cQC | gB 17701 | aC 240/415 V AC 240 V DC 80 V |
0.02 A...30 A 0.02 A...30 A 0.02 A...50 A |
| qPL Sweden Defence Material Admin. |
mIL-C- 55629 |
aC 240 V DC 50 V AC 240 V AC 240 / 415 V |
1 A...30 A (8340-F410) 1 A...30 A (8340-410) 1 A...30 A (8340-F420) 1 A...30 A (8340-F430) |
| Item name | 8340-F410-P1K1-A3H142-5A ETA Hydraulic magnetic circuit breaker |
|---|---|
| SKU | 24-01009 |
| Weight | 0.060800 |
| Characteristic | K1 Fast release characteristic hydraulically delayed DC |
| Output drive | P1 Flat plug DIN 46244-A6,3x0,8 |
| Colour and type of actuating element | A black |
| Auxiliary contact terminal form | Flachstecker DIN 46244-A2, 8-0,5 |
| Auxiliary contact function | 1 Wechsler |
| Auxiliary contact variants | H1 with auxiliary contacts, gold-plated |
| Dimension and shape | 4 with M3 fixing nuts |
| Country of manufacture | Germany |
| Accessories | 0 without accessories |
| Rated current | 5 A |
| Traub order number | 8340-F410-P1K1-A3H142-5A |
| Commodity code | 85362010 |
| Manufacturer | E-T-A |
| Manufacturer number | 8340-F410-P1K1-A3H142-5A |
| Number of poles | 1-pole protected |
| Mounting type | F Flange mounting |
| Series | 8340 |