3120-F75N-H7T1-A20Q-6A-X3120-U0000M ETA Thermal circuit breaker with undervoltage module

ETA thermal circuit breaker with undervoltage module
Combination circuit breaker / ON-OFF switch with rocker switch, front mounting
Rated current 6 Amp.

€51.34
Incl. 19% Tax, plus Shipping
Delivery within 1 to 3 days within Germany.
In stock
4 product are available
Article is running out, we have 4 items in stock
SKU
14-00147
3120-F75N-H7T1-A20Q-6A-X3120-U0000M ETA Thermal circuit breaker with undervoltage module is available to buy in increments of 1

Combination circuit breaker/ON-OFF switch with rocker switch, single or double pole, front mounting. Reliable switching behaviour due to uninfluenced free tripping. On-off switch without overcurrent protection or push-button on request. Fulfils the device protection standard EN 60934 (IEC 60934): S-type, TO. Meets the fire resistance requirements of EN 60335-1: 2007-2 Safety of household and similar electrical appliances.

The undervoltage module triggers the ON-OFF switch combination in the event of a voltage drop or failure. When the voltage returns, the switch combination must be deliberately switched on again to reconnect the load. An automatic restart of the load and the associated safety risk are thus excluded.

Attachment parts: Signal contact, magnetic release.

Typical areas of application:
Electric motors, household and office machines, electric tools, power supply units, charging rectifiers, medical equipment according to EN 60601

manufacturer:

eTA

rated voltage:

240 V AC; 50 V DC

rated current range:

0.1 - 20 A
(up to 30 A on request, 1-pole only)

dielectric strength:

actuation range Test voltage 3000 V AC
pole to pole (2-pole) Test voltage 1500 V AC

ambient temperature:

-30 - 60° C

mass:

approx. 33 g (2-pole)
approx. 27 g (1-pole)

protection class (IEC 60529):

actuating range IP 40
(with splash protection IP 54)
Connecting range IP 00

approvals:

vDE:

415 V AC-3 / 0.1 - 16 A (2-pole)
240 V AC / 0.1 - 20 A
50 V DC / 0.1 - 20 A (2-pole)
50 V DC / 0.1 - 4 A (1-pole)
28 V DC / 0.1 - 20 A

uL/CSA:

250 V AC / 0,1 - 20 A
250 V AC / 30 A (2 poles in parallel)
50 V DC / 0,1 - 20 A

More Information
Item name 3120-F75N-H7T1-A20Q-6A-X3120-U0000M ETA Thermal circuit breaker with undervoltage module
SKU 14-00147
Weight 0.052100
Country of manufacture Tunisia
Connection type Main connections H7 blade terminals, terminals 11 and 21 additionally with flat-head screws M 3.5 - standard for units with undervoltage module
Design: Communication, interface 01 analog Signal
Type N new design, stratos grey
Series 3120
Version 1 ohne galvanische Trennung
Manufacturer E-T-A
Manufacturer number 3120-U00385-6A
Additional function 0 ohne
Colour and lighting rocker 20. Rocker catana blue opaque without lighting
Rocker labelling Q Marking I and 0 pressed in
Actuating element A Design rocker switch
Undervoltage module X3120-U0000M Standard module
Operating voltage DC 24 V Nennspannung DC 24 V
Number of poles 2-pole, 1-pole thermally protected
Rated current range 6A
Mounting type F7 design version, installation opening 44.5x22mm, (clamping thickness 1-4mm)
Characteristic T1 thermal trip
Commodity code 85362010
Traub order number 3120-F75N-H7T1-A20Q-6A-X3120-U0000M
ETA Katalogseite (312.28 kB)

E-T-A
Elektrotechnische Apparate GmbH
Industriestraße 2-8
90518 Altdorf b. Nürnberg
Deutschland
order@e-t-a.de