1140-G151-P7M1-5A ETA Thermal circuit breaker
Thermal circuit breaker in small design
Two-pole with one protected pole
Rated current 5 Amp.
- Buy 10 for €22.44 each and save 16%
- Buy 100 for €12.99 each and save 51%
Artikel dem Warenkorb hinzufügen oder Alles auswählen
Double-pole circuit breaker with one thermally protected pole. Reliable switching behaviour due to snap-action switching mechanism and uninfluenced free tripping.
Complies with the appliance circuit breaker standard EN 60934 (IEC 60934): R-type, TO.
Typical applications:
Hand tools, household appliances, small transformers, office machines, mains and chargers, electric motors
Technical data:
| rated voltage | aC 240 V, DC 48 V |
| rated current | 0,4 A |
| service life AC & DC | 300 switching cycles with 2 x IN, inductive |
| ambient temperature | -20...60 °C (T60) |
| insulation coordination (IEC 60664) | 2.5 kV/2 reinforced insulation in the actuating area |
| dielectric strength | operating range Test voltage AC 3 000 V Pole/ Pole Test voltage AC 1 500V |
| insulation resistance | > 100 MΩ (DC 500 V) |
| switching capacity Icn | 6 x IN |
| breaking capacity (UL 1077) | iN 0.05...16 A AND DC 50 V 2 000 A IN 0.05...16 A AND AC 250 V 2 000 A |
| protection class (IEC 60529) | actuating range IP40 |
| connection range | iP00 |
| vibration resistance | 10 g (57-200 Hz), ± 0.76 mm (10-57Hz) Test according to IEC 60068-2-6, Test Fc, 10 frequency cycles per axis |
| shock resistance | 25 g (11 ms), Test according to IEC 60068-2-27, Test Ea |
| corrosion resistance | 96 h in 5 % salt spray, Test according to IEC 60068-2-11, Test Ka |
| humidity test | 240 hrs. in 95 % rel. humidity, Test according to IEC 60068-2-78, Test Cab |
| explosion tightness | test according to VG 95210, sheet 10 |
| mass | approx. 20.6 g |
approvals:
| test centre | test standard | rated voltage | rated current range |
| vDE | iEC/EN 60934 |
aC 240 V DC 48 V |
3.5 A...16 A 3.5 A...16 A |
| uL | uL 1077 | aC 250 V DC 50 V |
3.5 A...16 A 3.5 A...16 A |
| cSA | c22.2 No 235 | dC 28 V | 3.5 A...16 A 3.5 A...16 A |
| Item name | 1140-G151-P7M1-5A ETA Thermal circuit breaker |
|---|---|
| SKU | 24-01587 |
| Weight | 0.020400 |
| Country of manufacture | Tunisia |
| Accessories, design variant | 1 push button black (standard) |
| Connection type Main connections | P7 flat plug DIN 46244-C |
| Design: Communication, interface | 01 analog Signal |
| Series | 1140 |
| Version | 1 ohne galvanische Trennung |
| Manufacturer | E-T-A |
| Manufacturer number | 1140-G151-P7M1-5A |
| Additional function | 0 ohne |
| Actuating element | Push button |
| Undervoltage module | none |
| Operating voltage | DC 24 V Nennspannung DC 24 V |
| Number of poles | 2-pole, 1-pole protected |
| Mounting type | G1 threaded fastening with screwed-on hexagon and plastic knurled nut |
| Characteristic | M1 Medium time-lag tripping characteristic |
| Commodity code | 85362010 |
| Traub order number | 1140-G151-P7M1-5A |